1
|
- {"id":"DANDI:000489/draft","url":"https://dandiarchive.org/dandiset/000489/draft","name":"The impact of the second phase amplitude (% to the first phase) on the electroporation efficiency (measured as YP emission)","about":[],"access":[{"status":"dandi:OpenAccess","schemaKey":"AccessRequirements"}],"license":["spdx:CC-BY-4.0"],"version":"draft","@context":"https://raw.githubusercontent.com/dandi/schema/master/releases/0.6.4/context.json","citation":"Silkuniene, Giedre; Kim, Vitalii; Semenov, Iurii; Pakhomov, Andrei (2023) The impact of the second phase amplitude (% to the first phase) on the electroporation efficiency (measured as YP emission) (Version draft) [Data set]. DANDI archive. https://dandiarchive.org/dandiset/000489/draft","keywords":[],"protocol":[],"schemaKey":"Dandiset","identifier":"DANDI:000489","repository":"https://dandiarchive.org","contributor":[{"name":"Silkuniene, Giedre","email":"giedre.silkuniene@gmail.com","roleName":["dcite:ContactPerson"],"schemaKey":"Person","identifier":"0000-0001-8436-9718","affiliation":[],"includeInCitation":true},{"name":"Kim, Vitalii","roleName":[],"schemaKey":"Person","identifier":"0000-0003-0699-5582","affiliation":[],"includeInCitation":true},{"name":"Semenov, Iurii","roleName":[],"schemaKey":"Person","identifier":"0000-0002-0302-1355","affiliation":[],"includeInCitation":true},{"name":"Pakhomov, Andrei","roleName":[],"schemaKey":"Person","identifier":"0000-0003-3816-3860","affiliation":[],"includeInCitation":true},{"name":"National Institutes of Health","roleName":["dcite:Funder"],"schemaKey":"Organization","awardNumber":"1R21EY034258","contactPoint":[],"includeInCitation":false}],"dateCreated":"2023-04-21T18:50:06.335247+00:00","description":"Cells were electroporated by a train of 5 unipolar 600 ns pulses (0 percent) or bipolar 600 + 600 ns pulses (25, 50, 75, 100 percent) at 1 Hz. 25, 50, 75, and 100% represent the second pulse's amplitude in relation to the first pulse's amplitude. 0% represents a unipolar pulse, where no second pulse was applied. The electrodes were two parallel stainless-steel cylinders, 1.5 mm in diameter and 3 mm apart. Supported by NIH 1R21EY034258","studyTarget":[],"assetsSummary":{"schemaKey":"AssetsSummary","numberOfBytes":0,"numberOfFiles":0},"schemaVersion":"0.6.4","ethicsApproval":[],"wasGeneratedBy":[{"name":"Targeted Neuromodulation by Nanosecond Pulsed Electric Fields","used":[],"endDate":"2023-07-31T00:00:00-04:00","schemaKey":"Project","startDate":"2022-08-01T00:00:00-04:00","identifier":"1R21EY034258","wasAssociatedWith":[]}],"relatedResource":[{"url":"https://doi.org/10.1016/j.bioelechem.2022.108319","name":"Action spectra and mechanisms of (in) efficiency of bipolar electric pulses at electroporation","relation":"dcite:IsPublishedIn","schemaKey":"Resource"}],"manifestLocation":["https://api.dandiarchive.org/api/dandisets/000489/versions/draft/assets/"]}
|