1
|
- [{"approach":[],"schemaKey":"Asset","dateModified":"2024-06-10T15:58:29.068804-04:00","schemaVersion":"0.6.7","encodingFormat":"application/x-nwb","wasGeneratedBy":[{"name":"session_11","schemaKey":"Session","startDate":"2023-02-01T00:00:00-05:00","identifier":"session_11","description":"Subject ID: Cell11. General description of the experimental setup and conditions. Bath solution was composed of (in mM): 136 tetraethylammonium chloride (TEACl), 2 MgCl2, 10 CaCl2, 10 HEPES, and 10 glucose (pH 7.3, 300-310 mOsm/kg). Pipette solution contained (in mM): 20 TEACl, 130 CsCl, 10 HEPES, 4 Mg-ATP, 10 Cs-EGTA, and 0.12 of a fluorescent Ca2+ indicator Cal-520 (pH 7.3, 310 mOsm/kg). Pulse application: Patch clamp, voltage clamp mode, whole cell configuration with 0mV command voltage interrupted by 16 command voltage steps, 25 ms per step, applied at 350-ms intervals at 121 frame. Step voltage was escalated from -80 to -380 mV in 20-mV increments. Command voltage controlled via Multiclamp 700B amplifier and Digidata 1550B digitizer and Clampex 10.7 software (Molecular Devices, San Jose, CA)."},{"id":"urn:uuid:1885f9d3-ba11-4a55-b3bd-08b3bd7e5755","name":"Metadata generation","endDate":"2024-06-10T15:58:29.068804-04:00","schemaKey":"Activity","startDate":"2024-06-10T15:58:28.990043-04:00","description":"Metadata generated by DANDI cli","wasAssociatedWith":[{"url":"https://github.com/dandi/dandi-cli","name":"DANDI Command Line Interface","version":"0.62.0","schemaKey":"Software","identifier":"RRID:SCR_019009"}]}],"wasAttributedTo":[{"age":{"value":"P1D","unitText":"ISO-8601 duration","schemaKey":"PropertyValue","valueReference":{"value":"dandi:BirthReference","schemaKey":"PropertyValue"}},"sex":{"name":"Unknown","schemaKey":"SexType"},"species":{"name":"Homo sapiens - Human","schemaKey":"SpeciesType","identifier":"http://purl.obolibrary.org/obo/NCBITaxon_9606"},"schemaKey":"Participant","identifier":"Cell11"}],"blobDateModified":"2024-06-10T15:51:37.175023-04:00","variableMeasured":[],"measurementTechnique":[],"id":"dandiasset:f50880af-a813-495d-a3af-adb30c3da4fe","access":[{"schemaKey":"AccessRequirements","status":"dandi:OpenAccess"}],"path":"sub-Cell11/sub-Cell11_ses-session-11_image.nwb","identifier":"f50880af-a813-495d-a3af-adb30c3da4fe","contentUrl":["https://api.dandiarchive.org/api/assets/f50880af-a813-495d-a3af-adb30c3da4fe/download/","https://dandiarchive.s3.amazonaws.com/blobs/d91/d69/d91d698f-3afe-4a97-b489-865e2a1f4a17"],"contentSize":673717966,"digest":{"dandi:dandi-etag":"88205b941fa64844f102a54c9dc2adda-11","dandi:sha2-256":"d33fb53de9ced319f7bc1598f7d9033b0e4e2f61444d35abc77dd8c5550b5d19"},"@context":"https://raw.githubusercontent.com/dandi/schema/master/releases/0.6.7/context.json"},{"approach":[],"schemaKey":"Asset","dateModified":"2024-06-10T15:58:29.520223-04:00","schemaVersion":"0.6.7","encodingFormat":"application/x-nwb","wasGeneratedBy":[{"name":"session_03","schemaKey":"Session","startDate":"2023-02-01T00:00:00-05:00","identifier":"session_03","description":"Subject ID: Cell03. General description of the experimental setup and conditions. Bath solution was composed of (in mM): 136 tetraethylammonium chloride (TEACl), 2 MgCl2, 10 CaCl2, 10 HEPES, and 10 glucose (pH 7.3, 300-310 mOsm/kg). Pipette solution contained (in mM): 20 TEACl, 130 CsCl, 10 HEPES, 4 Mg-ATP, 10 Cs-EGTA, and 0.12 of a fluorescent Ca2+ indicator Cal-520 (pH 7.3, 310 mOsm/kg). Pulse application: Patch clamp, voltage clamp mode, whole cell configuration with 0mV command voltage interrupted by 16 command voltage steps, 25 ms per step, applied at 350-ms intervals at 121 frame. Step voltage was escalated from -80 to -380 mV in 20-mV increments. Command voltage controlled via Multiclamp 700B amplifier and Digidata 1550B digitizer and Clampex 10.7 software (Molecular Devices, San Jose, CA)."},{"id":"urn:uuid:cdb7235c-026e-44a5-839f-eb3f44ee8a72","name":"Metadata generation","endDate":"2024-06-10T15:58:29.520223-04:00","schemaKey":"Activity","startDate":"2024-06-10T15:58:29.406915-04:00","description":"Metadata generated by DANDI cli","wasAssociatedWith":[{"url":"https://github.com/dandi/dandi-cli","name":"DANDI Command Line Interface","version":"0.62.0","schemaKey":"Software","identifier":"RRID:SCR_019009"}]}],"wasAttributedTo":[{"age":{"value":"P1D","unitText":"ISO-8601 duration","schemaKey":"PropertyValue","valueReference":{"value":"dandi:BirthReference","schemaKey":"PropertyValue"}},"sex":{"name":"Unknown","schemaKey":"SexType"},"species":{"name":"Homo sapiens - Human","schemaKey":"SpeciesType","identifier":"http://purl.obolibrary.org/obo/NCBITaxon_9606"},"schemaKey":"Participant","identifier":"Cell03"}],"blobDateModified":"2024-06-10T15:49:19.241859-04:00","variableMeasured":[],"measurementTechnique":[],"id":"dandiasset:1f77e073-19f1-4d7c-b554-d5d9ed58b797","access":[{"schemaKey":"AccessRequirements","status":"dandi:OpenAccess"}],"path":"sub-Cell03/sub-Cell03_ses-session-03_image.nwb","identifier":"1f77e073-19f1-4d7c-b554-d5d9ed58b797","contentUrl":["https://api.dandiarchive.org/api/assets/1f77e073-19f1-4d7c-b554-d5d9ed58b797/download/","https://dandiarchive.s3.amazonaws.com/blobs/e92/4fa/e924fae0-ab6d-4552-9815-0f972781b112"],"contentSize":673506994,"digest":{"dandi:dandi-etag":"9915cf95c2b0a47ca4d2b2f58df894cf-11","dandi:sha2-256":"98ac4d065187a31c1d4027ca21cb8c4bf6df6f46b26a6f254926264487d9c4b8"},"@context":"https://raw.githubusercontent.com/dandi/schema/master/releases/0.6.7/context.json"},{"approach":[],"schemaKey":"Asset","dateModified":"2024-06-10T15:58:30.221729-04:00","schemaVersion":"0.6.7","encodingFormat":"application/x-nwb","wasGeneratedBy":[{"name":"session_07","schemaKey":"Session","startDate":"2023-02-01T00:00:00-05:00","identifier":"session_07","description":"Subject ID: Cell07. General description of the experimental setup and conditions. Bath solution was composed of (in mM): 136 tetraethylammonium chloride (TEACl), 2 MgCl2, 10 CaCl2, 10 HEPES, and 10 glucose (pH 7.3, 300-310 mOsm/kg). Pipette solution contained (in mM): 20 TEACl, 130 CsCl, 10 HEPES, 4 Mg-ATP, 10 Cs-EGTA, and 0.12 of a fluorescent Ca2+ indicator Cal-520 (pH 7.3, 310 mOsm/kg). Pulse application: Patch clamp, voltage clamp mode, whole cell configuration with 0mV command voltage interrupted by 16 command voltage steps, 25 ms per step, applied at 350-ms intervals at 121 frame. Step voltage was escalated from -80 to -380 mV in 20-mV increments. Command voltage controlled via Multiclamp 700B amplifier and Digidata 1550B digitizer and Clampex 10.7 software (Molecular Devices, San Jose, CA)."},{"id":"urn:uuid:f8ac9b7f-795e-49ab-8967-513024530b0f","name":"Metadata generation","endDate":"2024-06-10T15:58:30.221729-04:00","schemaKey":"Activity","startDate":"2024-06-10T15:58:29.748037-04:00","description":"Metadata generated by DANDI cli","wasAssociatedWith":[{"url":"https://github.com/dandi/dandi-cli","name":"DANDI Command Line Interface","version":"0.62.0","schemaKey":"Software","identifier":"RRID:SCR_019009"}]}],"wasAttributedTo":[{"age":{"value":"P1D","unitText":"ISO-8601 duration","schemaKey":"PropertyValue","valueReference":{"value":"dandi:BirthReference","schemaKey":"PropertyValue"}},"sex":{"name":"Unknown","schemaKey":"SexType"},"species":{"name":"Homo sapiens - Human","schemaKey":"SpeciesType","identifier":"http://purl.obolibrary.org/obo/NCBITaxon_9606"},"schemaKey":"Participant","identifier":"Cell07"}],"blobDateModified":"2024-06-10T15:50:49.898240-04:00","variableMeasured":[],"measurementTechnique":[],"id":"dandiasset:37e3e7e2-b840-4bfe-ab4a-2dbec886f448","access":[{"schemaKey":"AccessRequirements","status":"dandi:OpenAccess"}],"path":"sub-Cell07/sub-Cell07_ses-session-07_image.nwb","identifier":"37e3e7e2-b840-4bfe-ab4a-2dbec886f448","contentUrl":["https://api.dandiarchive.org/api/assets/37e3e7e2-b840-4bfe-ab4a-2dbec886f448/download/","https://dandiarchive.s3.amazonaws.com/blobs/01e/4d9/01e4d96d-ca50-4abb-9c6a-c22dac0d4381"],"contentSize":687891540,"digest":{"dandi:dandi-etag":"2d103b25e14e63e5d54810a37ed5277c-11","dandi:sha2-256":"bf346553efa59167076f4f902794493eacf0c7f27000e93a527194e3703a9152"},"@context":"https://raw.githubusercontent.com/dandi/schema/master/releases/0.6.7/context.json"},{"approach":[],"schemaKey":"Asset","dateModified":"2024-06-10T15:58:30.345883-04:00","schemaVersion":"0.6.7","encodingFormat":"application/x-nwb","wasGeneratedBy":[{"name":"session_12","schemaKey":"Session","startDate":"2023-02-01T00:00:00-05:00","identifier":"session_12","description":"Subject ID: Cell12. General description of the experimental setup and conditions. Bath solution was composed of (in mM): 136 tetraethylammonium chloride (TEACl), 2 MgCl2, 10 CaCl2, 10 HEPES, and 10 glucose (pH 7.3, 300-310 mOsm/kg). Pipette solution contained (in mM): 20 TEACl, 130 CsCl, 10 HEPES, 4 Mg-ATP, 10 Cs-EGTA, and 0.12 of a fluorescent Ca2+ indicator Cal-520 (pH 7.3, 310 mOsm/kg). Pulse application: Patch clamp, voltage clamp mode, whole cell configuration with 0mV command voltage interrupted by 16 command voltage steps, 25 ms per step, applied at 350-ms intervals at 121 frame. Step voltage was escalated from -80 to -380 mV in 20-mV increments. Command voltage controlled via Multiclamp 700B amplifier and Digidata 1550B digitizer and Clampex 10.7 software (Molecular Devices, San Jose, CA)."},{"id":"urn:uuid:903e2e01-51ea-44cb-8ffa-589a6c4ff0db","name":"Metadata generation","endDate":"2024-06-10T15:58:30.345883-04:00","schemaKey":"Activity","startDate":"2024-06-10T15:58:29.805799-04:00","description":"Metadata generated by DANDI cli","wasAssociatedWith":[{"url":"https://github.com/dandi/dandi-cli","name":"DANDI Command Line Interface","version":"0.62.0","schemaKey":"Software","identifier":"RRID:SCR_019009"}]}],"wasAttributedTo":[{"age":{"value":"P1D","unitText":"ISO-8601 duration","schemaKey":"PropertyValue","valueReference":{"value":"dandi:BirthReference","schemaKey":"PropertyValue"}},"sex":{"name":"Unknown","schemaKey":"SexType"},"species":{"name":"Homo sapiens - Human","schemaKey":"SpeciesType","identifier":"http://purl.obolibrary.org/obo/NCBITaxon_9606"},"schemaKey":"Participant","identifier":"Cell12"}],"blobDateModified":"2024-06-10T15:52:23.329614-04:00","variableMeasured":[],"measurementTechnique":[],"id":"dandiasset:71d366ea-4e08-49f4-bd0a-23a27513f456","access":[{"schemaKey":"AccessRequirements","status":"dandi:OpenAccess"}],"path":"sub-Cell12/sub-Cell12_ses-session-12_image.nwb","identifier":"71d366ea-4e08-49f4-bd0a-23a27513f456","contentUrl":["https://api.dandiarchive.org/api/assets/71d366ea-4e08-49f4-bd0a-23a27513f456/download/","https://dandiarchive.s3.amazonaws.com/blobs/192/bb6/192bb6ec-22d5-45f2-b9e7-699fce7cef26"],"contentSize":684378309,"digest":{"dandi:dandi-etag":"4654a9dd08b6404487c45876d0ab1c6e-11","dandi:sha2-256":"3a8ea413bd4ebf62971ef053521399d5caf28aff4537e5a6314f3a0d8a1484bb"},"@context":"https://raw.githubusercontent.com/dandi/schema/master/releases/0.6.7/context.json"},{"approach":[],"schemaKey":"Asset","dateModified":"2024-06-10T15:58:30.052236-04:00","schemaVersion":"0.6.7","encodingFormat":"application/x-nwb","wasGeneratedBy":[{"name":"session_04","schemaKey":"Session","startDate":"2023-02-01T00:00:00-05:00","identifier":"session_04","description":"Subject ID: Cell04. General description of the experimental setup and conditions. Bath solution was composed of (in mM): 136 tetraethylammonium chloride (TEACl), 2 MgCl2, 10 CaCl2, 10 HEPES, and 10 glucose (pH 7.3, 300-310 mOsm/kg). Pipette solution contained (in mM): 20 TEACl, 130 CsCl, 10 HEPES, 4 Mg-ATP, 10 Cs-EGTA, and 0.12 of a fluorescent Ca2+ indicator Cal-520 (pH 7.3, 310 mOsm/kg). Pulse application: Patch clamp, voltage clamp mode, whole cell configuration with 0mV command voltage interrupted by 16 command voltage steps, 25 ms per step, applied at 350-ms intervals at 121 frame. Step voltage was escalated from -80 to -380 mV in 20-mV increments. Command voltage controlled via Multiclamp 700B amplifier and Digidata 1550B digitizer and Clampex 10.7 software (Molecular Devices, San Jose, CA)."},{"id":"urn:uuid:66dbe927-1478-4212-8d32-57949ef9f342","name":"Metadata generation","endDate":"2024-06-10T15:58:30.052236-04:00","schemaKey":"Activity","startDate":"2024-06-10T15:58:29.686949-04:00","description":"Metadata generated by DANDI cli","wasAssociatedWith":[{"url":"https://github.com/dandi/dandi-cli","name":"DANDI Command Line Interface","version":"0.62.0","schemaKey":"Software","identifier":"RRID:SCR_019009"}]}],"wasAttributedTo":[{"age":{"value":"P1D","unitText":"ISO-8601 duration","schemaKey":"PropertyValue","valueReference":{"value":"dandi:BirthReference","schemaKey":"PropertyValue"}},"sex":{"name":"Unknown","schemaKey":"SexType"},"species":{"name":"Homo sapiens - Human","schemaKey":"SpeciesType","identifier":"http://purl.obolibrary.org/obo/NCBITaxon_9606"},"schemaKey":"Participant","identifier":"Cell04"}],"blobDateModified":"2024-06-10T15:50:03.216156-04:00","variableMeasured":[],"measurementTechnique":[],"id":"dandiasset:74f0ec66-2179-45c0-906b-e5766d9e7721","access":[{"schemaKey":"AccessRequirements","status":"dandi:OpenAccess"}],"path":"sub-Cell04/sub-Cell04_ses-session-04_image.nwb","identifier":"74f0ec66-2179-45c0-906b-e5766d9e7721","contentUrl":["https://api.dandiarchive.org/api/assets/74f0ec66-2179-45c0-906b-e5766d9e7721/download/","https://dandiarchive.s3.amazonaws.com/blobs/cc1/141/cc1141f5-98a3-4f9a-9f38-be9fc525f731"],"contentSize":750829353,"digest":{"dandi:dandi-etag":"00f482044b3a2fe81f8e357604f65ac8-12","dandi:sha2-256":"4268e82679f87a09bdf7f8edbd997b857dd536bc80d9b3ef146bb346bf4978d8"},"@context":"https://raw.githubusercontent.com/dandi/schema/master/releases/0.6.7/context.json"},{"approach":[],"schemaKey":"Asset","dateModified":"2024-06-10T15:59:26.311342-04:00","schemaVersion":"0.6.7","encodingFormat":"application/x-nwb","wasGeneratedBy":[{"name":"session_16","schemaKey":"Session","startDate":"2023-02-01T00:00:00-05:00","identifier":"session_16","description":"Subject ID: Cell16. General description of the experimental setup and conditions. Bath solution was composed of (in mM): 136 tetraethylammonium chloride (TEACl), 2 MgCl2, 10 CaCl2, 10 HEPES, and 10 glucose (pH 7.3, 300-310 mOsm/kg). Pipette solution contained (in mM): 20 TEACl, 130 CsCl, 10 HEPES, 4 Mg-ATP, 10 Cs-EGTA, and 0.12 of a fluorescent Ca2+ indicator Cal-520 (pH 7.3, 310 mOsm/kg). Pulse application: Patch clamp, voltage clamp mode, whole cell configuration with 0mV command voltage interrupted by 16 command voltage steps, 25 ms per step, applied at 350-ms intervals at 121 frame. Step voltage was escalated from -80 to -380 mV in 20-mV increments. Command voltage controlled via Multiclamp 700B amplifier and Digidata 1550B digitizer and Clampex 10.7 software (Molecular Devices, San Jose, CA)."},{"id":"urn:uuid:e90b2d37-ae82-44f3-83e9-bda44471f44c","name":"Metadata generation","endDate":"2024-06-10T15:59:26.311342-04:00","schemaKey":"Activity","startDate":"2024-06-10T15:59:26.244695-04:00","description":"Metadata generated by DANDI cli","wasAssociatedWith":[{"url":"https://github.com/dandi/dandi-cli","name":"DANDI Command Line Interface","version":"0.62.0","schemaKey":"Software","identifier":"RRID:SCR_019009"}]}],"wasAttributedTo":[{"age":{"value":"P1D","unitText":"ISO-8601 duration","schemaKey":"PropertyValue","valueReference":{"value":"dandi:BirthReference","schemaKey":"PropertyValue"}},"sex":{"name":"Unknown","schemaKey":"SexType"},"species":{"name":"Homo sapiens - Human","schemaKey":"SpeciesType","identifier":"http://purl.obolibrary.org/obo/NCBITaxon_9606"},"schemaKey":"Participant","identifier":"Cell16"}],"blobDateModified":"2024-06-10T15:53:49.954711-04:00","variableMeasured":[],"measurementTechnique":[],"id":"dandiasset:078d6fc0-5b89-488c-874e-9e88b752b89c","access":[{"schemaKey":"AccessRequirements","status":"dandi:OpenAccess"}],"path":"sub-Cell16/sub-Cell16_ses-session-16_image.nwb","identifier":"078d6fc0-5b89-488c-874e-9e88b752b89c","contentUrl":["https://api.dandiarchive.org/api/assets/078d6fc0-5b89-488c-874e-9e88b752b89c/download/","https://dandiarchive.s3.amazonaws.com/blobs/3d2/a0e/3d2a0e8e-f180-4a67-8d9f-32793dd243da"],"contentSize":668468227,"digest":{"dandi:dandi-etag":"954dd22d910bf87d5ed94c6eab11450a-10","dandi:sha2-256":"b11b5ae724294312a220508036eef4d26f69746d42286ba3444d363246e7a82b"},"@context":"https://raw.githubusercontent.com/dandi/schema/master/releases/0.6.7/context.json"},{"approach":[],"schemaKey":"Asset","dateModified":"2024-06-10T15:59:26.128522-04:00","schemaVersion":"0.6.7","encodingFormat":"application/x-nwb","wasGeneratedBy":[{"name":"session_13","schemaKey":"Session","startDate":"2023-02-01T00:00:00-05:00","identifier":"session_13","description":"Subject ID: Cell13. General description of the experimental setup and conditions. Bath solution was composed of (in mM): 136 tetraethylammonium chloride (TEACl), 2 MgCl2, 10 CaCl2, 10 HEPES, and 10 glucose (pH 7.3, 300-310 mOsm/kg). Pipette solution contained (in mM): 20 TEACl, 130 CsCl, 10 HEPES, 4 Mg-ATP, 10 Cs-EGTA, and 0.12 of a fluorescent Ca2+ indicator Cal-520 (pH 7.3, 310 mOsm/kg). Pulse application: Patch clamp, voltage clamp mode, whole cell configuration with 0mV command voltage interrupted by 16 command voltage steps, 25 ms per step, applied at 350-ms intervals at 121 frame. Step voltage was escalated from -80 to -380 mV in 20-mV increments. Command voltage controlled via Multiclamp 700B amplifier and Digidata 1550B digitizer and Clampex 10.7 software (Molecular Devices, San Jose, CA)."},{"id":"urn:uuid:93d36297-5101-4ab5-9004-7bcddbcd5d03","name":"Metadata generation","endDate":"2024-06-10T15:59:26.128522-04:00","schemaKey":"Activity","startDate":"2024-06-10T15:59:26.048411-04:00","description":"Metadata generated by DANDI cli","wasAssociatedWith":[{"url":"https://github.com/dandi/dandi-cli","name":"DANDI Command Line Interface","version":"0.62.0","schemaKey":"Software","identifier":"RRID:SCR_019009"}]}],"wasAttributedTo":[{"age":{"value":"P1D","unitText":"ISO-8601 duration","schemaKey":"PropertyValue","valueReference":{"value":"dandi:BirthReference","schemaKey":"PropertyValue"}},"sex":{"name":"Unknown","schemaKey":"SexType"},"species":{"name":"Homo sapiens - Human","schemaKey":"SpeciesType","identifier":"http://purl.obolibrary.org/obo/NCBITaxon_9606"},"schemaKey":"Participant","identifier":"Cell13"}],"blobDateModified":"2024-06-10T15:53:06.212046-04:00","variableMeasured":[],"measurementTechnique":[],"id":"dandiasset:89d30468-0174-446c-baea-869041d441dc","access":[{"schemaKey":"AccessRequirements","status":"dandi:OpenAccess"}],"path":"sub-Cell13/sub-Cell13_ses-session-13_image.nwb","identifier":"89d30468-0174-446c-baea-869041d441dc","contentUrl":["https://api.dandiarchive.org/api/assets/89d30468-0174-446c-baea-869041d441dc/download/","https://dandiarchive.s3.amazonaws.com/blobs/5ab/d03/5abd038c-b5ac-4e25-b6ef-47d08c85d74d"],"contentSize":650483528,"digest":{"dandi:dandi-etag":"3a57c91dfdd94f1e7e68c5b517e9c0ad-10","dandi:sha2-256":"5432b244b96d7f51c55dfd7604f2e17aaf5b4ac61538bb70685e2f00e16c08c5"},"@context":"https://raw.githubusercontent.com/dandi/schema/master/releases/0.6.7/context.json"}]
|